  • Eaton HDXL rack PDU G4

    Eaton HDXL rack PDU G4 is an ultra-high-power rack PDU specifically engineered for AC-powered AI, GPU and HPC environments, helping data center operators support rack densities up to 140+ kW rack infrastructures with minimal footprint and deliver the power required for next-generation AI applications.
    Contact me about this product View resources

Purpose-built for AI and high-performance computing

Catalog Number Technology Form Factor Plug Type Phase Voltage Current Outlets Power Rating Input cable Length
EVMAXL140 Managed 0U (Vertical) Hardwired 3P 240/415V 140A (24) C39 81 kW N/A
EVMAXL100 Managed 0U (Vertical) 5100P6W 3P 240/415V 100A (24) C39 58 kW 6.56 ft
EVMOXL140 Metered Outlet 0U (Vertical) Hardwired 3P 240/415V 140A (24) C39 81 kW N/A
EVMOXL100 Metered Outlet 0U (Vertical) 5100P6W 3P 240/415V 100A (24) C39 58 kW 6.56 ft
spacer
Eaton HDXL rack PDU G4 EVMAXL140
Support up to 81 kW per PDU and 140+ kW per rack
Build N+X redundancy with a smaller footprint
Save room for cooling, networking, and compute
Zero-trust architecture with UL and IEC cybersecurity certifications

Designed for the future of AI infrastructure

Hot-swappable network module

The hot-swappable Gigabit Network Module (GNM) can be removed or upgraded without interrupting power to the PDU. With dual GbE ports, you can easily cascade up to 32 PDUs and share the same network connection with individual IP addresses, simplifying management, freeing up space and cutting costs.

Implementing Zero-Touch Provisioning with Eaton gigabit network interfaces

Market-leading cybersecurity

The HDXL rack PDU G4 includes a user-configurable firewall. Managed and metered input models offers market-leading cybersecurity capabilities, including zero-trust architecture and zero-touch provisioning via the integrated gigabit network module. It is the only PDU on the market with UL 2900-1 and IEC 62443-4-2 cybersecurity certifications.

Maximize your investment with software

For larger deployments spanning multiple locations, the HDXL rack PDU G4 integrates smoothly via SNMP with digital solutions from our Brightlayer Data Centers suite. This includes Distributed IT software and DCIM software, and our cloud-based Remote Monitoring Service, also known as PredictPulse™, which is an around-the-clock service that aggregates data from your rack PDUs and dispatches an Eaton field technician when a critical event occurs.

Find the right rack PDU for your IT needs

Specify basic, metered input, metered outlet or managed PDUs, also known as switched PDUs, in addition to several other key features.

P-Lock power cords eliminate accidental cable disconnections in a crowded PDU

Outlets that give you options

High-retention, P-lock compatible C39 outlets accept both C14 and C20 plugs, adding flexibility to deployments and reducing the quantity of PDUs you will need to purchase and install. Fewer PDUs also means more rack space for revenue-generating equipment.

 